Votronic charging converter, B2B battery-to-battery charger VCC 1212-50
Votronic charging converter, B2B battery-to-battery charger VCC 1212-50

Votronic charging converter, B2B battery-to-battery charger VCC 1212-50

Article no.: 108741
Manufacturer: Votronic

Offer is exclusively for commercial customers. Prices are only visible after login.

  • Product description
  • Technical details
  • High charging power evenfor shortdistances orfull charging for longer journeys.
  • Increases/decreases the voltage to the necessary level to be able to charge the on-board battery precisely with the optimum charging characteristic curve.
  • Fully compensates for line losses and voltage fluctuations of the dynamo, as they occur to a considerable extent e.g. inEuro 6 vehicles (intelligent alternators).The dynamo fully compensates for line losses and voltage fluctuations of the alternator, which occur to a considerable extent in Euro6 vehicles(intelligent alternators).
  • Compact design, low weight (high-frequency switch mode technology) and power components with strong dimensions for safe operation.
  • Significantly betterenergy balance of theon-board battery without intervention in the starter circuit
  • 12 V consumers supplied with power are protected against overvoltage and voltage fluctuations.
  • The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is ruled out.
  • Fully automatic operation:The unit is permanently connected to the batteries and is automatically activated by the vehicle's running dynamo. When the engine is not running, the batteries are not discharged.
  • Parallel and buffer operation: In the event of simultaneous consumption, the battery is further charged or kept full. The unit automatically calculates and monitors the adjustment of the charging times.
  • Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short-circuit, malfunction and battery back-discharge by electronic cut-off up to complete disconnection of unit and battery.
  • Built-in on-board power supply filter: Problem-free parallel operation with other charging sources (EBL, chargers, motor and fuel generators, solar systems) on one battery.
  • Charging cable compensation: Voltage losses on the charging cables are automatically compensated.
  • Connection for battery temperature sensor(included): For lead batteries (acid, gel, AGM), the charging voltage is automatically adapted to the battery temperature, resulting in better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing in summer temperatures.
  • LiFePO4 batteries: Battery protection at high and especially at low temperatures < 0°C.
  • Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support of the battery with consumers possibly still switched on.

    • C
    • harging

      programmes1

      "Gel": Charging programme for gel batteries, characteristic IU1oU2oU3
      Adapted to sealed, gas-tight gel/dryfit batteries with fixed electrolyte, which generally require a higher charging voltage level and longer U1 holding times in order to achieve short charging times with particularly high capacity storage and to avoid long-term battery "starvation".

      2"AGM": Charging programme for AGM/fleece batteries, characteristic IU1oU2oU3
      Intended for charging sealed, gas-tight AGM (Absorbent-Glass-Mat) batteries in lead-fleece technology, which require a particularly high U1 level with coordinated holding times for full charging and then a moderate U2 level for charge retention (plate and round cell technology).

      4 "UNIVERSAL": Charging programme for lead-acid/wet/AGM batteries, characteristic IU1oU2oU3
      Universal programme for charging and charge retention of acid batteries in vehicles (mixed mobile/stationary). With medium U1 level, still offers short charging times, good charging factor and good acid mixing for open and closed, low-maintenance, maintenance-free standard, drive, lighting, solar and heavy-duty batteries, as well as AGM batteries with normal U1 level.

      Li "LiFePO4": Charging programme for lithium batteries, characteristic IU1oU2oU3
      Charging programme adapted to lithium LiFePO4 batteries with their own BMS and prescribed or built-in protective circuitry.

    • High charging power evenfor shortdistances orfull charging for longer journeys.
    • Increases/decreases the voltage to the necessary level to be able to charge the on-board battery precisely with the optimum charging characteristic.
    • Completely compensates for line losses and voltage fluctuations of the dynamo, as they constantly occur to a considerable extent inEuro6 vehicles(intelligent alternators), for example.
    • Compact design, low weight (high-frequency switch mode technology) and powerfully dimensioned power components for safe operation.
    • Significantly betterenergy balance of theon-board battery without intervention in the starter circuit
    • 12 V consumers supplied with power are protected against overvoltage and voltage fluctuations.
    • The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is ruled out.
    • Fully automatic operation:The unit is permanently connected to the batteries and is automatically activated by the vehicle's running dynamo. When the engine is not running, the batteries are not discharged.
    • Parallel and buffer operation: In the event of simultaneous consumption, the battery is further charged or kept full. The unit automatically calculates and monitors the adjustment of the charging times.
    • Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short-circuit, malfunction and battery back-discharge by electronic cut-off up to complete disconnection of unit and battery.
    • Built-in on-board power supply filter: Problem-free parallel operation with other charging sources (EBL, chargers, motor and fuel generators, solar systems) on one battery.
    • Charging cable compensation: Voltage losses on the charging cables are automatically compensated.
    • Connection for battery temperature sensor(included): For lead batteries (acid, gel, AGM), the charging voltage is automatically adapted to the battery temperature, resulting in better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing in summer temperatures.
    • LiFePO4 batteries: Battery protection at high and especially at low temperatures < 0°C.
    • Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support of the battery with consumers possibly still switched on.

      • C
      • harging

        programmes1

        "Gel": Charging programme for gel batteries, characteristic IU1oU2oU3
        Adapted to sealed, gas-tight gel/dryfit batteries with fixed electrolyte, which generally require a higher charging voltage level and longer U1 holding times in order to achieve short charging times with particularly high capacity storage and to avoid long-term battery "starvation".

        2"AGM": Charging programme for AGM/fleece batteries, characteristic IU1oU2oU3
        Intended for charging sealed, gas-tight AGM (Absorbent-Glass-Mat) batteries in lead-fleece technology, which require a particularly high U1 level with coordinated holding times for full charging and then a moderate U2 level for charge retention (plate and round cell technology).

        4 "UNIVERSAL": Charging programme for lead-acid/wet/AGM batteries, characteristic IU1oU2oU3
        Universal programme for charging and charge retention of acid batteries in vehicles (mixed mobile/stationary). With medium U1 level, still offers short charging times, good charging factor and good acid mixing for open and closed, low-maintenance, maintenance-free standard, drive, lighting, solar and heavy-duty batteries, as well as AGM batteries with normal U1 level.

        Li "LiFePO4": Charging programme for lithium batteries, characteristic IU1oU2oU3
        Charging programme adapted to lithium LiFePO4 batteries with their own BMS and prescribed or built-in protective circuitry.

      • High charging power evenfor shortdistances orfull charging for longer journeys.
      • Increases/decreases the voltage to the necessary level to be able to charge the on-board battery precisely with the optimum charging characteristic.
      • Completely compensates for line losses and voltage fluctuations of the dynamo, as they constantly occur to a considerable extent inEuro6 vehicles(intelligent alternators), for example.
      • Compact design, low weight (high-frequency switch mode technology) and powerfully dimensioned power components for safe operation.
      • Significantly betterenergy balance of theon-board battery without intervention in the starter circuit
      • 12 V consumers supplied with power are protected against overvoltage and voltage fluctuations.
      • The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is ruled out.
      • Fully automatic operation:The unit is permanently connected to the batteries and is automatically activated by the vehicle's running dynamo. When the engine is not running, the batteries are not discharged.
      • Parallel and buffer operation: In the event of simultaneous consumption, the battery is further charged or kept full. The unit automatically calculates and monitors the adjustment of the charging times.
      • Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short-circuit, malfunction and battery back-discharge by electronic cut-off up to complete disconnection of unit and battery.
      • Built-in on-board power supply filter: Problem-free parallel operation with other charging sources (EBL, chargers, motor and fuel generators, solar systems) on one battery.
      • Charging cable compensation: Voltage losses on the charging cables are automatically compensated.
      • Connection for battery temperature sensor(included): For lead batteries (acid, gel, AGM), the charging voltage is automatically adapted to the battery temperature, resulting in better full charging of the weaker battery in cold weather, and avoiding unnecessary battery gassing in summer temperatures.
      • LiFePO4 batteries: Battery protection at high and especially at low temperatures < 0°C.
      • Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support of the battery with consumers possibly still switched on.

        • C
        • harging

          programmes1

          "Gel": Charging programme for gel batteries, characteristic IU1oU2oU3
          Adapted to sealed, gas-tight gel/dryfit batteries with fixed electrolyte, which generally require a higher charging voltage level and longer U1 holding times in order to achieve short charging times with particularly high capacity storage and to avoid long-term battery "starvation".

          2"AGM": Charging programme for AGM/fleece batteries, characteristic IU1oU2oU3
          Intended for charging sealed, gas-tight AGM (Absorbent-Glass-Mat) batteries in lead-fleece technology, which require a particularly high U1 level with coordinated holding times for full charging and then a moderate U2 level for charge retention (plate and round cell technology).

          4 "UNIVERSAL": Charging programme for lead-acid/wet/AGM batteries, characteristic IU1oU2oU3
          Universal programme for charging and charge retention of acid batteries in vehicles (mixed mobile/stationary). With medium U1 level, still offers short charging times, good charging factor and good acid mixing for open and closed, low-maintenance, maintenance-free standard, drive, lighting, solar and heavy-duty batteries, as well as AGM batteries with normal U1 level.

          Li "LiFePO4": Charging programme for lithium batteries, characteristic IU1oU2oU3
          Charging programme adapted to lithium LiFePO4 batteries with their own BMS and prescribed or built-in protective circuitry.

        • Input from the vehicle starter battery "+ IN Start"
          Vehicle Starter Battery Nominal Voltage12 V
          Min. Battery Capacity (Size), recommended60 Ah
          Input Voltage Range (EURO 6+), D+, controlled10.5 - 16.5 V
          Input Overvoltage Disconnection (EURO 6+), max.16.5 V
          Power Consumption max.760 W
          Current Draw (at lowest input voltage) max.0.1 A - 68 A
          Current Draw Limited, 3 Switch Positions "IN Limit"49 A, 42 A, 33 A
          Auxiliary Charging, Charge/Trickle Charg. 12 V Starter Battery
          for External Mains Charging Mode, Switch Position "B"0 - 3 A
          Activation Control Input "D+", from D+, Terminal 15, Ignition8 - 16.5 V
          IN "Start" Voltage Sensor Cables "Vs-" and "Vs+"yes / yes
          Terminal "TR", Signal for Bypass Relay / max.12 V / 1 A
          Charging Port at the Board Supply Battery "+ OUT Board"
          Charging/Floating/Load Curr., controlled, IU1oU2, Lead, LiFePO0 A - 50 A
          Reduction at Switch Position "OUT Limit"0 A - 39 A
          Lead-Acid, Gel, AGM Batteries Nominal Voltage12 V
          Capacity (Battery Size), recommended / up to75-320 / 440 Ah
          Lead Charging Programs Stored in the Memory4
          Prelim. Charg. Current (Deeply Discharged Batt. <8 V) max.25 A
          Safety Charging Voltage at Battery Overtemperature12.80 V
          LiFePO4 Battery Nominal Voltage12 V (12.8 -13.3 V)
          Capacity (Battery Size), recommended / up to75-320 / 440 Ah
          LiFePO4 Charging Programs Stored in the Memory4
          Safety Charging Voltage at Battery Overtemperature12.80 V
          Input "T T" for Battery Temperature Sensor "Board"yes
          OUT "Board" Voltage Sensor Cables "Vb-" and "Vb+"yes / yes
          Quiescent Current, Standby16 mA
          Charging Timer3-fold
          Ripple Factor Voltage< 30 mV rms
          Limit of Charging Voltage "+OUT Board" (Consumer Protection)15.00 V
          External Overvoltage Disconnection "+OUT Board" (20 sec.)15.50 V
          Safety Protection against Short-circuit/Back Dischargeyes
          Fitting Position of Unitany
          Temperature Range-20 to 45° C
          Speed-controlled, Temperature-controlled Fanyes
          Gradual Reduction of Charging Capacity at Overtemperatureyes
          Safety Disconnection in Case of Overheatingyes
          Dimensions, incl. Fastening Flanges and Terminals (LxWxH)135 x 160 x 72 mm
          Weight950 g
          Ambient Conditions, Humidity of Air: max. 95 % RH, no condensation
          Delivery Scope: Temperature Sensor, Manual